IMPROVEMENT
OF RADIOGRAPHY BY FCR
Low contrast indication on normal radiograph will be improved
with FCR processing. These data will keep in optical disk
and be stored easily.
We can make minimize the unavailable radiation at site. |
|
|
 |
SCALE
CHECKER SHOW PIPE CONDITION
Our developed easy handling SCALE CHECKER will inspect inside
pipes without films. Choked condition & stuck rate of
pipes can be shown quickly.
APPLICATION
Flow condition of Towers and Vessels in Chemical Plants,
Stuck hard scale in Resolution tubes in Oil Refinery
|
|
|
TUBE THICKNESS GAUGING
WITH IRIS SYSTEM
Continuous thickness measurement for Heat exchanger tubes
will be performed with accuracy. Sectional drawing of tube
wall can be seen on CRT and print out. |
|
|

|
|
|
|
|
INSIDE
SCALE THICK. MEASUREMENT OF BOILER TUBES
Magnetite and other scales stuck inside of boiler tubes
will decrease the efficiency of heat exchanging. We developed
our own accurate measurement method for such thinner scale
layer without any sampling.
|
|

|
|
|
 |
EDDY CURRENT
TEST FOR NON-MAGNETIC METAL TUBES
We have long experience of Eddy Current test at site for non-magnetic
metal tubes and store enough data in Oil refinery , Chemical
, Power plants. and Ships.
|
|
|
 |
REMOTE FIELD
EDDY CURRENT TEST (RFT) for STEEL TUBES
Remote field eddy current test has been possible to test Ferro-Magnetic
metal tubes same as non-magnetic tubes.
We started earlier this testing and now got good estimation
of clients.
|
|
|
|
|
MAG BIAS
METHOD FOR ALUMINA COATING TUBES
We tried to spread ET application for specified tubes.
Mag-Bias method is useful to detect subsurface corrosion hidden
by aluminum coating.
|
|
|
|
|
TUBE THICKNESS
MEASUREMENT BY OPTICAL LASER
Determination of remaining tube's life installed in Heat exchanger
has been done with extreme analysis on sampling tubes. We
applied Optical Laser to measure wall thickness continuously.
The statistical calculation will be done automatically by
PC.
|
|
|
ULTRA-RED VIEW INSPECTION BY THERMOVIEWER
We introduced high sensitive NIKON THERMOVIEWER for monitoring
the operating condition of instruments and to find invisible
damage hidden in concrete structures.
|
|
|
HELIUM LEAK TEST
Leak tests will be performed to confirm the safety and airtight
of each vessel. We have enough experiences to evalvate the
airtightness at site include it's planning and evaluation.
APPLICATION
Ammonia Leak test / Halogen Leak test |
|
|

|
|
|
|

|
UNDERGROUND INSPECTION
BY PORTABLE RADAR
Portable Radar will find out invisible underground pipe line
for maintenance and voids to keep safety driving on road.
APPLICATION
Reinforced bar detection in concrete walls by portable device.
|
|
| |
| |